Input Voltage | 90 - 264 VAC (127 - 370 VDC) | Input Frequency | 47 - 63 Hz |
Inrush Current | < 48 Amps; Measured at 264 VAC, 25°C Ambient, Cold start |
No Load Power | < 0.5 W |
Output Voltage | 5 V to 48 V |
Output Power | 60 W |
Voltage Tolerance | ± 1 % |
Line Regulation | < 1% of Vout |
Load Regulation | ± 1 % |
Turn On Time | < 1 sec @ 230 VAC & < 3 sec @ 115 VAC, Full load |
Hold Up Time | ≥60ms at 230V AC & ≥15ms at 115V AC, Full load |
Rise Time | < 100 ms |
Overload Protection | > 110% of rated output current; Hiccup type; Autorecovery |
Overvoltage Protection | Latched type; Input AC power to be recycled to recover the power supply |
Output Short Circuit Protection | Hiccup mode when output is shorted; Autorecovery type |
Over Temperature | Power supply shuts down when the temperature of PCB below main transformer reaches typically 120°C |
Operating Temp | - 25°C to + 70°C; De-rate linearly above 50°C from 100 % load at 50°C to 50 % load at 70°C,- 25°C to 0°C start-up is guaranteed with specification deviation |
Storage Temp | - 40°C to + 85°C |
Cooling | Natural convection cooled |
Humidity | 5 to 95 % RH, Non condensing |
Altitude | 2000 m |
Dimension | 4” x 2” x 1.16” (L x W x H); Height above PCB: 1” |
Weight | < 150 gms |
Mounting | Open Frame |